Creative Engineering - Header
Home › Blog › Corrosion Material Guide

Material Selection for Acids & Chlorides: HCl, H2SO4, Hastelloy, Titanium & Glass-Lined

Which material survives hydrochloric acid, sulphuric acid, chlorides, caustic and solvents? A practical corrosion guide to SS 316L, Duplex, Hastelloy, titanium, glass-lined and lined equipment for reactors, tanks, columns and heat exchangers in chemical plants.

Skid mounted process equipment manufactured by Creative Engineering

Quick Answer

For hydrochloric acid and strong chlorides, standard stainless steel (304, 316L) fails quickly; Hastelloy, titanium, glass-lined steel or rubber, PTFE or FRP lining are used instead. For sulphuric acid, the right material depends on concentration and temperature: carbon steel for concentrated cold acid, higher alloys or lined equipment for dilute or hot acid. Always confirm with corrosion data for your exact conditions.

Why Material Selection Decides Equipment Life

In a chemical plant, the most expensive mistake is a vessel that corrodes through in a few months. A reactor, tank or heat exchanger does not fail because of pressure alone; it fails when the wall is thinned, pitted or cracked by the fluid it holds. Choosing the right material of construction (MOC) at the design stage protects safety, product purity and uptime. The correct choice depends on the chemical, concentration, temperature, velocity, presence of chlorides, impurities, oxygen and whether the service is continuous or intermittent. Because these factors interact, published corrosion tables are a starting point, not a final answer. Always confirm material choice with your process licensor, corrosion data or a corrosion specialist.

Creative Engineering fabricates equipment in SS 304, SS 316L, Duplex, Hastelloy, titanium, carbon steel and lined construction. Our material selection overview compares the main grades; this guide goes deeper into acids and chlorides.

Types of Corrosion You Must Design Against

Type What happens Where it appears Typical remedy
General corrosion Even loss of wall thickness Carbon steel in acids; stainless in strong acids Corrosion allowance or a more resistant alloy
Pitting Small deep holes Stainless steel in chloride solutions 316L, Duplex or Hastelloy; avoid stagnant liquid
Crevice corrosion Attack under gaskets and deposits Flanges, welds, under deposits Better gasket design, cleanliness, higher alloy
Stress corrosion cracking Cracking under tensile stress in a specific environment 300-series stainless with chlorides at warm temperature Duplex or nickel alloys, lower stress
Intergranular corrosion Attack at grain boundaries after welding Non-low-carbon stainless after welding Use L grades (304L, 316L) or stabilised grades
Erosion corrosion Wear from flow plus corrosion Elbows, nozzles, agitators Lower velocity, harder or better alloy
Galvanic corrosion Two metals in contact in an electrolyte Dissimilar metals joints Insulate or match metals
Process skid fabricationSkid mounted equipment

Hydrochloric Acid (HCl): The Hardest Common Service

Hydrochloric acid is aggressive to nearly all stainless steels at almost any concentration, because chlorides break down the protective oxide layer. Even dilute, warm HCl can corrode 316L quickly. For this reason, HCl service usually uses non-metallic or highly alloyed materials:

  • Glass-lined steel: excellent for HCl at a wide range of concentrations, with limits on thermal shock and mechanical damage.
  • Rubber lined, PTFE or PFA lined steel: economical for tanks, pipes and some vessels, with temperature limits.
  • FRP and polypropylene: used for storage tanks, scrubbers and piping at moderate temperature.
  • Hastelloy C-276 and similar nickel alloys: handle many HCl conditions but cost much more; suitability depends on concentration and temperature.
  • Titanium: not suitable for pure reducing HCl, unless inhibited by oxidising impurities; seek data before use.
  • Tantalum and graphite: used for special heat exchangers and absorbers.
Rule of thumb: do not use SS 304 or 316L for hot or concentrated hydrochloric acid, and avoid them for any wet chloride service unless the temperature, concentration and chloride content are clearly low and confirmed.

Sulphuric Acid (H2SO4): Concentration and Temperature Matter

Sulphuric acid behaves differently across its concentration range, so one material cannot be chosen without knowing both concentration and temperature. Strong, cold sulphuric acid (above about 90 percent) forms a protective film on carbon steel, so carbon steel tanks are widely used for storage. In the medium range, such as 40 to 80 percent, corrosion is more severe and carbon steel and many stainless steels are unsuitable; high-silicon iron, alloys such as Alloy 20 or Hastelloy, or lined construction are considered. Dilute sulphuric acid is aggressive to carbon steel but can be handled by certain stainless steels at lower temperature, or by lined and plastic equipment.

Concentration Typical option Caution
Concentrated (above about 90%), cold Carbon steel Hot or diluted acid attacks quickly; avoid water ingress
Medium (about 40 to 80%) Alloy 20, Hastelloy or lined steel Aggressive; temperature has a large effect
Dilute (below about 30%) 316L at low temperature, lined steel, FRP or PP Check temperature and impurities
Oleum (fuming) Carbon steel or special alloys Specialist design needed

Values above are general indications only. Final material selection must rest on corrosion data for your exact acid, temperature and impurities.

Chlorides, Brine and Seawater

Chloride ions are a leading cause of pitting, crevice corrosion and stress corrosion cracking of stainless steel. Mild chloride exposure may be acceptable for SS 316L at low temperature, but higher chloride, higher temperature and low pH raise the risk sharply. In these cases, Duplex and super Duplex stainless steels, nickel alloys or titanium offer far better resistance. Titanium is widely used in seawater and brine heat exchangers because of its excellent resistance to chloride attack. For stressed parts such as welded vessels at elevated temperature, avoid 300-series stainless in chloride service unless the risk has been assessed. Clean equipment well after use and avoid leaving chloride-containing liquid to dry on surfaces.

Caustic, Organic Acids and Solvents

  • Caustic soda: carbon steel and stainless steel handle moderate concentrations at lower temperature; higher temperature needs nickel alloys because of caustic cracking.
  • Organic acids (acetic, formic): 316L is commonly used for acetic acid; formic acid and hot, concentrated acids may need higher alloys.
  • Nitric acid: stainless steel such as 304L performs well; carbon steel is not suitable.
  • Phosphoric acid: 316L is common; impurities such as fluorides and chlorides change the choice.
  • Chlorinated solvents: can generate HCl in the presence of moisture and heat, so choose materials as if for wet HCl in risk areas.
  • Polar and non-polar solvents: SS 316L and carbon steel are widely used; check elastomers, gaskets and seals for compatibility.

Glass-Lined, Rubber-Lined and Plastic-Lined Equipment

When metals cannot economically resist the process, a lining or non-metallic material can be used. Glass-lined steel offers excellent resistance to most acids and is common in reactors for pharma and fine chemicals, but it is sensitive to thermal shock, impact and strong alkalis at high temperature. Rubber lining suits acid and chloride storage tanks at moderate temperatures. PTFE and PFA lining handles many aggressive chemicals but needs careful design to avoid permeation and vacuum collapse. FRP and polypropylene tanks are economical for atmospheric storage. Lined equipment needs strict handling, inspection and repair routines, and cannot be welded in the field once lined.

Cost vs Life: Comparing Material Options

The cheapest material at purchase is often the most expensive over the life of the plant. A carbon steel vessel that corrodes in two years and needs replacement costs more than an alloy vessel that lasts fifteen. When comparing options, include purchase price, expected corrosion rate, inspection and maintenance cost, downtime, product contamination risk and replacement cost.

Option Relative cost Typical strengths Typical limits
Carbon steel Low Strong, economical, easy to fabricate Corrodes in many acids and wet chlorides; may contaminate product
SS 304 / 304L Medium Good general resistance, hygienic Weak against chlorides and strong acids
SS 316 / 316L Medium to high Better pitting resistance, pharma standard Not for hot HCl or strong chlorides
Duplex and super Duplex High High strength, good chloride resistance Needs controlled welding; temperature limits
Hastelloy and nickel alloys Very high Wide resistance, including many acids High cost and long lead time
Titanium Very high Excellent in chlorides and oxidising media Not for strong reducing acids
Glass or rubber lined steel Medium to high Resists many acids at lower cost than alloys Handling and temperature limits, no field welding

A short life-cycle cost comparison at the design stage often justifies a higher-grade material.

Quick Selection Table for Common Chemicals

Chemical Common material options Avoid or check
Dilute HCl Glass-lined, rubber, PTFE, FRP, Hastelloy SS 304 and 316L
Concentrated H2SO4 (cold) Carbon steel Water dilution, hot acid
Dilute H2SO4 Lined steel, FRP, PP, Alloy 20 Carbon steel
Nitric acid SS 304L, 316L Carbon steel
Acetic acid SS 316L Hot concentrated acid with contaminants
Chlorides, brine Duplex, super Duplex, titanium SS 304
Caustic (hot, strong) Nickel alloys SS 304 and 316L at high temperature
Alcohols, ketones, esters SS 304, 316L, carbon steel Elastomer compatibility
Pharma solvents and APIs SS 316L, electro-polished Carbon steel contamination

Treat this table as a guide only; every process has its own impurities and conditions.

Fabrication Practices That Protect Corrosion Resistance

  • Use low-carbon or stabilised grades to avoid intergranular attack after welding.
  • Control heat input and use matching filler metal for Duplex and nickel alloys.
  • Pickle and passivate stainless steel after welding to restore the protective film.
  • Avoid carbon steel tools, brushes and contamination on stainless surfaces.
  • Ensure crevice-free welds and smooth internal finish for easier cleaning.
  • Design for drainability so that corrosive liquid does not stagnate.
  • Check gasket, seal and elastomer compatibility for every chemical.
  • Document material heat numbers and keep positive material identification (PMI) records.

See our GMP equipment design guide for surface finish and passivation details, and our inspection guide for corrosion monitoring in service.

How We Help You Choose

Share your chemical list with concentrations, temperature range, pressure and cleaning methods, and our engineers will suggest suitable material options for your reactor, tank, column or heat exchanger. We can fabricate in stainless steel, Duplex, Hastelloy, titanium and carbon steel, and coordinate lined construction where required. Read our reactor price factors guide to see how material affects cost. Send your enquiry through the contact page or call +91 98251 38460. We are located in Ankleshwar, Gujarat, and serve plants across India.

Frequently Asked Questions

Can SS 316L be used for hydrochloric acid?

Generally no. Hydrochloric acid and chloride-rich solutions corrode 316L quickly; lined equipment, Hastelloy or non-metallic materials are used instead.

Which material is best for sulphuric acid?

It depends on concentration and temperature: carbon steel for cold concentrated acid, and alloys or lined and plastic equipment for dilute or hot acid.

What is the difference between pitting and crevice corrosion?

Pitting forms small holes on an open surface, while crevice corrosion starts in shielded areas such as under gaskets and deposits.

Is titanium resistant to chlorides?

Yes, titanium resists chloride attack very well, which is why it is used for seawater and brine exchangers, but it is not suitable for every acid.

What is glass-lined equipment used for?

It handles many acids in reactors for pharma and fine chemicals, but it is sensitive to impact and thermal shock.

Why use L-grade stainless steel?

Low-carbon grades such as 304L and 316L resist intergranular corrosion after welding.

Can Creative Engineering build in Hastelloy and titanium?

Yes. We fabricate in SS 304, SS 316L, Duplex, Hastelloy, titanium and carbon steel, and can coordinate lined construction.

Need a quotation or technical help?

Creative Engineering, Ankleshwar, Gujarat designs and manufactures process equipment to ASME and IBR codes. Share your drawing or process data and our team will respond with a technical offer.

Request a Quote